UK - As well as an extensive PA system, RG Jones Sound Engineering has also installed the Ampetronic induction loop system to meet DDA requirements and ensure the enjoyment of its hard of hearing members and visitors to Wimbledon's All England Club.

"Outside of the two week Championships - when we are continually on site monitoring the courtside PA, umpires microphones and so forth - there are requirements from the Club to use parts of the system throughout the year," explains RG Jones's Jon Berry. "The main areas that are used are the Centre Court facilities, which include a range of bars and restaurants. These are used for private functions and it's in some of these that we've installed the loop systems."

There are seven spaces covered by the loops, and these are situated either next to or on top of each other. "It was quite a mission," says Berry. "We had to use phased array floor mounted loops so that we could control not just the horizontal spill, but the vertical spill as well."

The entire Centre Court system is controlled from one of three PA rooms, and this is where the ILD1000G amplifiers for the loop system are also housed.

"We have all the amplifiers here," says Berry. "We've found that using the ILD1000Gs is a much better solution than previous amps as they're so much more powerful and take up less room.

"As the amplifiers are housed remotely from the loops, we've had to install them all with feed cables using Star Quad cable because of the length of the run. In some cases, we have 120m long cable, but it works very well and there is no cross talk at all. Additionally, everything is backed up by a UPS, so if the power fails, then it will carry on going with the rest of the PA system."

Installation of the system presented its own set of challenges. During construction, a large number of contractors were working on the floor, so it was hard for RG Jones to get it clear to lay the tapes.

"Also, in some areas the flooring is ceramic tile, which meant we couldn't use copper tape," continues Jon. "We used a cable that is resistant to alkalis instead and had the builders chase a channel into the floor in the pattern of the phased array.

"The system works well and everyone involved is very pleased with it," concludes Berry. "We came up with new ways to do things and ways to get around problems, and we've learnt a lot that we can take with us to the next challenge."

(Jim Evans)


Latest Issue. . .

Save
Cookies user preferences
We use cookies to ensure you to get the best experience on our website. If you decline the use of cookies, this website may not function as expected.
Accept all
Decline all
Analytics
Tools used to analyze the data to measure the effectiveness of a website and to understand how it works.
Google Analytics
Accept
Decline
Advertisement
If you accept, the ads on the page will be adapted to your preferences.
Google Ad
Accept
Decline